S116 – meters and sensors.

The temperature sensitive element of a resistive temperature sensor is an ideal device for continuous temperature monitoring inside cryo-storages, programmable freezers. SINTESY temperature sensors are RTD (resistance temperature sensors), made of platinum, two-wire, class A, and can measure temperature in a wide range of values from -200°C up to + 100°C.

Measurement tolerance is about ± 0.15°C at 0°C and remains below 0.5°C even at the extreme values of the measuring range. Sensor tolerance is usually adjusted during the calibration process using a reference sample.

Version Sensor type Range min. Range max. Diameter Length of a thermometer Cable length
S116-01 PT100 -196°C +100°C 3,0 mm 15 mm 2,5 m
S116-02 PT100 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-03 PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-11 PT1000 -80°C +100°C 3,0 mm 40 mm 2,5 m
S116-12 PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-13 PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-21
S2000-
PT1000-1
PT1000 -80°C +100°C 3,0 mm 40 mm 2,5 m
S116-22
S2000-
PT1000-2
PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-31 PT1000 -80°C +100°C 3,0 mm 40 mm 2,5 m
S116-32 PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m
S116-33 PT1000 -80°C +100°C 3,0 mm 40 mm 2,5 m
S116-34 PT1000 -196°C +100°C 3,0 mm 40 mm 2,5 m

Популярное

Laboratory module WB-230

Laboratory module WB-230

Laboratory module WB-230 with cryogenic working area and three independent program freezers.
EC-180/4

EC-180/4

EuroCyl-180/4 pressurized cryogenic vessel with capacity of 196 liters for transportation, storage of cryogenic liquids and delivery of liquefied gases. For laboratory and industrial applications.
MVE YDS-30L

MVE YDS-30L

Dewar vessel MVE YDS-30L, volume 31,5 l for transportation and storage of liquid nitrogen.Designed for laboratory and industrial use.
YDS-30-125-FH

YDS-30-125-FH

Dewar vessel YDS-30-125-FH with a volume of 31,5 liters with additional side and bottom reinforcement for increased safety during transportation and storage of biological samples.
Pipe cooling button S187 Sintesy

Pipe cooling button S187 Sintesy

Pipe cooling button S187 Sintesy is a button for autonomous control and monitoring of cooling of the cryogenic pipelines, controlled from a cryobank/biobank.
MVE HE 1879P-190

MVE HE 1879P-190

The MVE HE 1879 P-190 cryogenic storage facility provides stable cryogenic storage of up to 79950 1.2 / 2.0 ml cryoprobes.