Laboratory module WB-220

Article: AS-A0.2562.0000
Price:
Production: Germany
Germany
Description Characteristics

Laboratory module WB-220 with cryogenic working area and two independent program freezers. It is a working space for processing, sorting, recovery and packaging of the biomaterial samples at temperatures from -100°C to room temperature. For laboratory use.

Dimensions (WxDxH), mm 1860х970х2030
Empty weight, kg 300
Weight at full load, kg 450
Working pressure, bar 0
Electric drive for height adjustment Adjustable range 30 cm (option)
Openings for operator hands Two, closed with gloves (heated gloves as option)
Barcode reader Built-in, one-dimensional/two-dimensional (option)
Quantity of independent program freezers with lift 2
Working temperature range From room temperature to -100°C
Temperature range in the freezer zone From + 15°C to -160°C
Resolution of temperature values ​​on the display 0.01°C
Temperature deviation ± 2.5°C (from the target freezing curve)
Cooling speed in freezer 0.01-50 deg/min
Cooling rate of samples
Usually 10 deg/min (depending on the volume of samples, format and material)
Time to reach operating temperature Max. 45 minutes (for working area -100°C)
Control system PC with 15" LCD touch screen, on a moving stand
Connection to laboratory / hospital information system
Customizable software interface (based on customer requirements)
Power supply
Maximum power consumption is 1000 Wt (230V, 50Hz)
Refrigerant Liquid nitrogen (LN2)

Популярное

Supergap SGxxHF/SS

Supergap SGxxHF/SS

Supergap atmospheric vaporizers are manufactured by Chart Ferox in the Czech Republic. The evaporators have a wide range of models: capacity from 50 to 4,000 Nm3 / hour, pressure from 40 to 400 bar. Supergap ...
YDS-20-LYS

YDS-20-LYS

Dewar vessel YDS-20-LYS with a volume of 20 liters with additional side and bottom reinforcement for increased safety during transportation and storage of biological samples.
PU-303

PU-303

The withdrawing device PU-303 for transfer liquid nitrogen from Dewar vessels CK-6 into another container due to small overpressure. For laboratory and general industrial applications.
PU-301

PU-301

The withdrawing device PU-301 for transfer liquid nitrogen from Dewar vessels CK-16 into another container due to small overpressure. For laboratory and general industrial applications.
SC 2/1V

SC 2/1V

The MVE SC 2/1V dewar vessel provides storage of 88 1/2 мл straws , 182 1/4 мл straws and 0 vials for 8 days. Holds 1,5 liters of liquid nitrogen.
YDZ-500 / YDZ-500K

YDZ-500 / YDZ-500K

The YDZ-500 / YDZ-500K vessel with a capacity of 500 liters, designed for pressures up to 1.5 bar, is used for storing and dispensing liquid nitrogen at a rate of ≥ 10 L/min. It is intended for both laboratory ...